What is EC, what is CF, what is ppm, what is TDS, what is mS/cm and uS/cm?A. They are all different types of readings used especially in hydroponics so we know the strength of the nutrient solution the plants are growing in. CF stands for Conductivity Factor. This is exactly the same as Electrical Conductivity (EC), but does not have a decimal point in the reading. ppm is parts per million. This is not a measure of electrical conductivity in a nutrient solution, therefore cannot be accurately measured by an EC meter. They are present on the Bluelab Truncheon as a conversion guide only and the scales of ppm they represent are noted. To convert from EC to ppm, simply multiply EC by the ppm scale required, e.g. 2.5EC x 500scale ppm = 1250ppm. The two scales Bluelab use are; 700ppm and 500ppm scale. There are many ppm scales around, but these two are most common. TDS is Total Dissolved Solids. This is the 500ppm scale. mS/cm2 - millisiemens per cm. 1 mS/cm = 10CF uS/cm2 - microsiemens per cm One millisiemen = 1000 microsiemens Check out our Conductivity Converter for easy conversions of conductivity. You may also view or print our Measurement Conversion Chart.
|